1. Introduction
CO removal catalyst could be used to remove CO from petro gas, inert gas, oxygen and etc, also could be used in various furnace like oven, chimney place, incinerator to treat not burst CO. Before using, CO removal catalystshould be heated up to 180~200℃ by fresh air, in order to active its performance. The best operating temperature: 250℃-300℃, after light-off, shut down automatically compensate for heating. If the temperature is up to or above 550℃, cool the reactor by heat transfer and recover heat energy. This catalyst could make CO content less than 0.5ppm under space velocity at 1.0~3.0×103 h-1, T02-1 has high crushing strength, with service life at least 2 years.
2. Chemical information
Coating
>10.0 wt%
Activity component
could be vary with your requirement
Expulsion rate
<1%
3. Physical parameter
Item Value
Catalyst carrier material alumina + cordierite
Specs size depends on operating condition and your demand
Appearance Light brown honeycomb
Space velocity ≥1×103 h-1
Light-off temperature 100℃-150℃
Operating temperature 250℃-300℃
CO removal ratio ≥98﹪
Service life ≥2 years
CO outlet content <5ppm
Bulk density 0.68±0.05g/mL
Crushing strength ≥14 MPa
Package moisture-proof
Suggested loading ratio 4:01
Height : diameter